35kv ct pt test equipment
"
0.05% CT PT Test Equipment Phase Angle Error Measurement
0.05% Standard Bench Type CT PT Test Equipment Test Bench HES-10 System Configuration: 1) HES-10 CT&PT Test Bench 2) HES-1C Digital Transformer Tester 3) FY49 Current Transformer Burden (5A/1A optional) 4) HLS-30G2 Standard Current Transformer ( with Current Source) 5) FY95 Voltage Transformer ...
Cabinet Type CT PT Test Equipment System Error Measurement
Cabinet Type CT PT Test Bench System MCHZDZ-3Z System Configuration 1) HZDT Fully automatic Cabinet type Control Bench 2) Digital Transformer Tester 3) Current Transformer Burden (5A/1A optional) 4) Standard Current Transformer ( with Current Source) 5) Voltage Transformer Burden 6) Standard Voltage ...
0.05S Class CT PT Test Equipment With Auto Protection
Portable CT PT Test Equipment System HEW-15 1) Can test error, impedance and admittance of CT & PT 2) Fast test speed and accurate data 3) With auto protection for polarity reverse connection, indication of wrong wiring & error beyond range 4) Auto save test data, and print in local test site, also ...
0.01S Class Standard 5000A 38.5KV CT PT Test Equipment System
CT PT TEST Equipment System HES-30 Configuration Standard CT, ±0.01S% Standard PT (6kV-38.5kV), ±0.05% CT Burden (5A, 1A), ±3% PT Burden (100V, 100/√3V, 100/3V), ±3% PT Burden (110V, 110/√3V, 110/3V), ±3% Transformer Tester (Calibrator), ±2% Current generator Voltage Generator Secondary Test Cables ...
0.02S Class CT PT Testing Equipment , 3200A Current Transformer Testing Equipment
0.02S Standard Current Transformer CT PT Test Equipment Test System 1) Error test (Ratio error and Phase error) of CT&PT 2) Manual operation or operation through PC by software Test range: Measure Item Test Range CT accuracy test Rated primary current range: 1A-3200A Rated secondary current: 5A, 1A ...
500VA CT PT Test Equipment , Portable CT PT Analyser
Portable PT Test Equipment MPT01 Technical Index Accuracy class 0.05 Voltage ratio test range 6~66kV/100V 6/√3~110√3kV/100/√3V 6kV/100V,(6/√3)kV/(100/√3)V, 6.6kV/100V,(6.6/√3)kV/(100/√3)V,10kV/100V,(10/√3)kV/(100/√3)V,35kV/100V,(35/√3)kV/(100/√3)V,66kV/100V,(66/√3)kV/(100/√3)V,and(110/√3)kV/(100/√3...
CT PT TEST Equipment 3150A HES-10 CT&PT Accuracy Test System
HES-10 CT & PT Accuracy Testing System System Configuration HES-10 CT&PT Test Bench HES-1C Digital Transformer Tester FY49 Current Transformer Burden (5A/1A optional) HLS-30G2 Standard Current Transformer ( with Current Source) FY95 Voltage Transformer Burden (100V,100/√3V or other ratio requirement...
CT PT 220KV Portable Test Equipment With PC Communication Interface
CT PT TEST Equipment System HES-30 Configuration Standard CT, ±0.01S% Standard PT (6kV-38.5kV), ±0.05% Standard PT (110/√3kV, 220/√3kV), ±0.05% CT Burden (5A, 1A), ±3% PT Burden (100V, 100/√3V, 100/3V), ±3% PT Burden (110V, 110/√3V, 110/3V), ±3% Transformer Tester (Calibrator), ±2% Current generator ...
1A Current Transformer Test Equipment , 0.02S Current Transformer Tester
0.02S Standard Current Transformer CT PT Test Equipment Test System Measure Item Test Range CT accuracy test Rated primary current range: 1A-3200A Rated secondary current: 5A, 1A Operation range: (1%-120%).In PT accuracy test Rated primary voltage (kV): 6, 6/√3, 10, 10/√3, 15, 15/√3, 22, 22/√3, 35, ...