lcd ct pt test equipment
"
Comparador del equipo de prueba de Digitaces CT pinta con la exhibición del LCD
Digital Transformer Tester HEW series CT PT Comparator Technical Parameter Accuracy class 2 Current range 5A, 1A Voltage range 100V,100/√3V Percentage Error Less than 1.5%*FS Basic Error When testing CT PT error & impedance & admittance, the error will not beyond: ΔX=±(X*2%+Y*2%+Dx) ΔY=±(X*2%+Y*2%...
Equipo de prueba de 60HZ CT pinta con la caja de la carga del transformador corriente
Intelligent Type Current Transformer Burden Box CT Burden FY61A Technical Parameter Rated Current 5A, 1A Operating Range 1-120% Rated Impedance (Ω) COSφ= 0.8 0.1;0.15;0.2;0.3;0.4;;0.6;1.0;1.2; 1.6; 2.4; 3.2 COSφ= 1.0 0.1;0.15;0.2;0.3;0.4 Rated Frequency 50/60HZ Basic Error Active (±3+0.003*100/R)%·R...
0.01S sistema estándar del equipo de prueba de la clase 5000A 38.5KV CT pinta
CT PT TEST Equipment System HES-30 Configuration Standard CT, ±0.01S% Standard PT (6kV-38.5kV), ±0.05% CT Burden (5A, 1A), ±3% PT Burden (100V, 100/√3V, 100/3V), ±3% PT Burden (110V, 110/√3V, 110/3V), ±3% Transformer Tester (Calibrator), ±2% Current generator Voltage Generator Secondary Test Cables ...
equipo de prueba del CT pinta de la clase 0.01S, sistema de la prueba del transformador corriente 220KV
CT PT TEST Equipment System HES-30 Technical Parameter HES-30 CT/PT Test Bench Input Voltage: AC 220V±10%, 50Hz, Single-Phase Input Current: AC 0-120A Rated Capacity: 30kVA Output Voltage: AC 0-250V Output Current: AC 0-120A HES-1Bx Transformer Tester Measure item: Ratio errors & Phase errors of the ...
Equipo de prueba del CT pinta de la pantalla táctil del 3% como carga secundaria
Intelligent Type Potential Transformer Burden Box VT Burden FY96 Technical Parameter Rated Current 100V, 100/√3, 110V, 110/√3more (option) Operating Range 1-200% Rated load (VA) COSφ= 0.8: 1.25-158.75 Rated Frequency 50 or 60HZ Basic Error Active (±3%·g(ms) Reactive (±3%·b(ms) Test voltage: 2KV One ...
Sistema de la prueba del CT pinta del error del ángulo de fase
Digital Transformer Tester HEWE series CT PT Test Equipment Comparator Technical Parameter Accuracy class 2 Current range 5A, 1A Voltage range 100V,100/√3V Percentage Error Less than 1.5%*FS Basic Error When testing CT PT error & impedance & admittance, the error will not beyond: ΔX=±(X*2%+Y*2%+Dx) ...
Equipo de prueba portátil del CT pinta 220KV con el interfaz de comunicaciones de la PC
CT PT TEST Equipment System HES-30 Configuration Standard CT, ±0.01S% Standard PT (6kV-38.5kV), ±0.05% Standard PT (110/√3kV, 220/√3kV), ±0.05% CT Burden (5A, 1A), ±3% PT Burden (100V, 100/√3V, 100/3V), ±3% PT Burden (110V, 110/√3V, 110/3V), ±3% Transformer Tester (Calibrator), ±2% Current generator ...
puerto de USB portátil de la pantalla táctil del equipo de prueba del metro 12A
Portable Meter Test Equipment Three Phase Reference Standard Meter MCST01 Technical Parameters Current Measure Direct mode range 1mA-12A Clamp-on CT mode range 5A, 100A, 300A…...2000A (optional) Rogowski Coil mode 3000A…5000A…10000A (optional) Accuracy 0.05% (10mA-12A) 0.2% (clamp-on CT mode) 1% ...
pantalla táctil trifásica portátil del equipo de prueba del metro 12A RSM WIFI Moudle
12A Portable Meter Test Equipment Three Phase RSM Touch Screen WIFI moudle Technical Data Sheet Current testing Range (direct mode current) 1mA-12A Range (clamp-on CT mode current) 5A, 100A, 300A…...2000A (optional) Range (Rogowski Coil mode current) 3000A…5000A…10000A (optional) Accuracy 0.05% ...