lcd ct pt test equipment
"
Comparador digital de equipos de ensayo CT PT con pantalla LCD
Digital Transformer Tester HEW series CT PT Comparator Technical Parameter Accuracy class 2 Current range 5A, 1A Voltage range 100V,100/√3V Percentage Error Less than 1.5%*FS Basic Error When testing CT PT error & impedance & admittance, the error will not beyond: ΔX=±(X*2%+Y*2%+Dx) ΔY=±(X*2%+Y*2%...
Equipo de ensayo CT PT de 60 Hz con caja de carga del transformador de corriente
Intelligent Type Current Transformer Burden Box CT Burden FY61A Technical Parameter Rated Current 5A, 1A Operating Range 1-120% Rated Impedance (Ω) COSφ= 0.8 0.1;0.15;0.2;0.3;0.4;;0.6;1.0;1.2; 1.6; 2.4; 3.2 COSφ= 1.0 0.1;0.15;0.2;0.3;0.4 Rated Frequency 50/60HZ Basic Error Active (±3+0.003*100/R)%·R...
0.01S Sistema de equipos de ensayo CT PT de la norma de clase 5000A de 38,5 KV
CT PT TEST Equipment System HES-30 Configuration Standard CT, ±0.01S% Standard PT (6kV-38.5kV), ±0.05% CT Burden (5A, 1A), ±3% PT Burden (100V, 100/√3V, 100/3V), ±3% PT Burden (110V, 110/√3V, 110/3V), ±3% Transformer Tester (Calibrator), ±2% Current generator Voltage Generator Secondary Test Cables ...
0.01S Equipo de ensayo CT PT de clase, conjunto de ensayo de transformadores de corriente de 220 KV
CT PT TEST Equipment System HES-30 Technical Parameter HES-30 CT/PT Test Bench Input Voltage: AC 220V±10%, 50Hz, Single-Phase Input Current: AC 0-120A Rated Capacity: 30kVA Output Voltage: AC 0-250V Output Current: AC 0-120A HES-1Bx Transformer Tester Measure item: Ratio errors & Phase errors of the ...
Equipo de prueba CT PT con pantalla táctil del 3% como carga secundaria
Intelligent Type Potential Transformer Burden Box VT Burden FY96 Technical Parameter Rated Current 100V, 100/√3, 110V, 110/√3more (option) Operating Range 1-200% Rated load (VA) COSφ= 0.8: 1.25-158.75 Rated Frequency 50 or 60HZ Basic Error Active (±3%·g(ms) Reactive (±3%·b(ms) Test voltage: 2KV One ...
Ángulo de Fase Error CT PT Conjunto de Pruebas
Digital Transformer Tester HEWE series CT PT Test Equipment Comparator Technical Parameter Accuracy class 2 Current range 5A, 1A Voltage range 100V,100/√3V Percentage Error Less than 1.5%*FS Basic Error When testing CT PT error & impedance & admittance, the error will not beyond: ΔX=±(X*2%+Y*2%+Dx) ...
Equipo de prueba portátil CT PT 220KV con interfaz de comunicación de PC
CT PT TEST Equipment System HES-30 Configuration Standard CT, ±0.01S% Standard PT (6kV-38.5kV), ±0.05% Standard PT (110/√3kV, 220/√3kV), ±0.05% CT Burden (5A, 1A), ±3% PT Burden (100V, 100/√3V, 100/3V), ±3% PT Burden (110V, 110/√3V, 110/3V), ±3% Transformer Tester (Calibrator), ±2% Current generator ...
Equipo de prueba de medidores portátil de 12 A con pantalla táctil y puerto USB
Portable Meter Test Equipment Three Phase Reference Standard Meter MCST01 Technical Parameters Current Measure Direct mode range 1mA-12A Clamp-on CT mode range 5A, 100A, 300A…...2000A (optional) Rogowski Coil mode 3000A…5000A…10000A (optional) Accuracy 0.05% (10mA-12A) 0.2% (clamp-on CT mode) 1% ...
Equipo de prueba de medidores portátil 12A trifásico con pantalla táctil y módulo WIFI
12A Portable Meter Test Equipment Three Phase RSM Touch Screen WIFI moudle Technical Data Sheet Current testing Range (direct mode current) 1mA-12A Range (clamp-on CT mode current) 5A, 100A, 300A…...2000A (optional) Range (Rogowski Coil mode current) 3000A…5000A…10000A (optional) Accuracy 0.05% ...