lcd ct pt test equipment
"
Digital CT PT Test Equipment Comparator With LCD Display
Digital Transformer Tester HEW series CT PT Comparator Technical Parameter Accuracy class 2 Current range 5A, 1A Voltage range 100V,100/√3V Percentage Error Less than 1.5%*FS Basic Error When testing CT PT error & impedance & admittance, the error will not beyond: ΔX=±(X*2%+Y*2%+Dx) ΔY=±(X*2%+Y*2%...
60HZ CT PT Test Equipment With Current Transformer Burden Box
Intelligent Type Current Transformer Burden Box CT Burden FY61A Technical Parameter Rated Current 5A, 1A Operating Range 1-120% Rated Impedance (Ω) COSφ= 0.8 0.1;0.15;0.2;0.3;0.4;;0.6;1.0;1.2; 1.6; 2.4; 3.2 COSφ= 1.0 0.1;0.15;0.2;0.3;0.4 Rated Frequency 50/60HZ Basic Error Active (±3+0.003*100/R)%·R...
0.01S Class Standard 5000A 38.5KV CT PT Test Equipment System
CT PT TEST Equipment System HES-30 Configuration Standard CT, ±0.01S% Standard PT (6kV-38.5kV), ±0.05% CT Burden (5A, 1A), ±3% PT Burden (100V, 100/√3V, 100/3V), ±3% PT Burden (110V, 110/√3V, 110/3V), ±3% Transformer Tester (Calibrator), ±2% Current generator Voltage Generator Secondary Test Cables ...
0.01S Class CT PT Test Equipment , 220KV Current Transformer Test Set
CT PT TEST Equipment System HES-30 Technical Parameter HES-30 CT/PT Test Bench Input Voltage: AC 220V±10%, 50Hz, Single-Phase Input Current: AC 0-120A Rated Capacity: 30kVA Output Voltage: AC 0-250V Output Current: AC 0-120A HES-1Bx Transformer Tester Measure item: Ratio errors & Phase errors of the ...
3% Touch Screen CT PT Test Equipment As Secondary Load
Intelligent Type Potential Transformer Burden Box VT Burden FY96 Technical Parameter Rated Current 100V, 100/√3, 110V, 110/√3more (option) Operating Range 1-200% Rated load (VA) COSφ= 0.8: 1.25-158.75 Rated Frequency 50 or 60HZ Basic Error Active (±3%·g(ms) Reactive (±3%·b(ms) Test voltage: 2KV One ...
Phase Angle Error CT PT Test Set
Digital Transformer Tester HEWE series CT PT Test Equipment Comparator Technical Parameter Accuracy class 2 Current range 5A, 1A Voltage range 100V,100/√3V Percentage Error Less than 1.5%*FS Basic Error When testing CT PT error & impedance & admittance, the error will not beyond: ΔX=±(X*2%+Y*2%+Dx) ...
CT PT 220KV Portable Test Equipment With PC Communication Interface
CT PT TEST Equipment System HES-30 Configuration Standard CT, ±0.01S% Standard PT (6kV-38.5kV), ±0.05% Standard PT (110/√3kV, 220/√3kV), ±0.05% CT Burden (5A, 1A), ±3% PT Burden (100V, 100/√3V, 100/3V), ±3% PT Burden (110V, 110/√3V, 110/3V), ±3% Transformer Tester (Calibrator), ±2% Current generator ...
12A Portable Meter Test Equipment Touch Screen USB port
Portable Meter Test Equipment Three Phase Reference Standard Meter MCST01 Technical Parameters Current Measure Direct mode range 1mA-12A Clamp-on CT mode range 5A, 100A, 300A…...2000A (optional) Rogowski Coil mode 3000A…5000A…10000A (optional) Accuracy 0.05% (10mA-12A) 0.2% (clamp-on CT mode) 1% ...
12A Portable Meter Test Equipment Three Phase RSM Touch Screen WIFI Moudle
12A Portable Meter Test Equipment Three Phase RSM Touch Screen WIFI moudle Technical Data Sheet Current testing Range (direct mode current) 1mA-12A Range (clamp-on CT mode current) 5A, 100A, 300A…...2000A (optional) Range (Rogowski Coil mode current) 3000A…5000A…10000A (optional) Accuracy 0.05% ...