Quality Phase Angle Error CT PT Test Set factory
<
Quality Phase Angle Error CT PT Test Set factory
>

Phase Angle Error CT PT Test Set

Product Summary

Digital Transformer Tester HEWE series CT PT Test Equipment Comparator Technical Parameter Accuracy class 2 Current range 5A, 1A Voltage range 100V,100/√3V Percentage Error Less than 1.5%*FS Basic Error When testing CT PT error & impedance & admittance, the error will not beyond: ΔX=±(X*2%+Y*2%+Dx) ...

Product Custom Attributes

Accuracy Class:
2
Current Range1:
1A, 5A
Voltage Range:
100V、100/√3V
Test Function:
Ratio, Ratio Error, Phase Angle Error......
Percentage Error:
Less Than 1.5%*FS
Display:
Big LCD
Highlight:

1.5%FS CT PT Test Set

,

1.5%FS 100V CT PT Test Set

,

5A 1.5%FS ratio ct and pt testing

Basic Properties

Place of Origin:
China
Brand Name:
HNMC
Model Number:
HEWE series

Trading Properties

Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Wooden Package
Delivery Time:
30-45 days
Payment Terms:
L/C, T/T, Western Union
Supply Ability:
30 sets per month

Product Description

 

Digital Transformer Tester HEWE series CT PT Test Equipment Comparator

 

 

Technical Parameter

Accuracy class 2
Current range 5A, 1A
Voltage range 100V,100/√3V
Percentage Error Less than 1.5%*FS
Basic Error
When testing CT PT error & impedance & admittance, the error will not beyond:

ΔX=±(X*2%+Y*2%+Dx)

ΔY=±(X*2%+Y*2%+Dy)

ΔX: basic error limit value of in-phase component

ΔY: basic error limit value of Quadrature Component

X: Indication absolute value of in-phase component

Y: Indication absolute value of Quadrature Component

Dx & Dy: Zero error and Quantizing Error

When testing CT & PT, Dx,Dy=1(or 2)%*(Error limit value of CT & PT

When testing Z & Y, Dx,Dy= 3 digits

 

Measure Range & Resolution

CT PT class Test Range Resolution
In-phase component Quadrature Component In-phase component Quadrature Component
0.01 ±0.4000 ±13.752 0.0001% 0.001'
0.02
0.05
0.1 ±4.000 ±137.52 0.001% 0.01'
0.2
0.5
1.0 ±40.00 ±999.9 0.01% 0.1'
Impedance Measure Range & Resolution
Range Measure Range (Ω) Resolution
5A ±1.000 0.0001
1A ±6.000 0.0001
Admittance Measure Range & Resolution
Range Measure Range (mS) Resolution
100V ±9.9999 0.0001
57.7V ±9.9999 0.0001

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Features

 

1) LCD display

2) Test of ratio, ratio error, phase angle error, impedance, admittance

3) Test data values are all displayed

4) Used for testing of class 1 to 0.01 instrument transformer with rated current 5A and 1A, 

    rated voltage 100V, 100V√3V

5) Display ratio error & phase angle error of all test points under rated burden or lower limit

    burden 1%-120% Rated current or 20%-120% rated voltage

 

Phase Angle Error CT PT Test Set

                                            Design for options

Contact Our Experts And Get A Free Consultation!

Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.