Product Summary
Partial Discharge Detector MCPD002 Use advanced technology and provide better user experience Provide more functions optional for client High stability and reliable performance High accuracy measurement Customization available according to user special requirement Five channels options for more ...
Product Custom Attributes
Handheld Partial Discharge Test Equipment
,300KHZ Partial Discharge Test Equipment
,1% Partial Discharge Detector
Basic Properties
Trading Properties
Product Description
Partial Discharge Detector MCPD002
Use advanced technology and provide better user experience
Provide more functions optional for client
High stability and reliable performance
High accuracy measurement
Customization available according to user special requirement
Five channels options for more accessories choices
Suitable for lab, worksite online measurement
Widely used in power utilties, maintenance company
Comptitive price with good quality comparing with Europe brand
Technical Index
1. TEV measurement
| Item | Specification |
| Sensor | capacitance type |
| Range | 0-60bBmV |
| Frequency range | 3-100MHz |
| Resolution | 1dB |
| Accuracy | ±1dB |
| Maximum impulse/cycles qty | 1400 |
| Minimum impulse rate | 10Hz |
2. Ultrasonic Measurement
| Item | Specification |
| Range | -7dBuV~68dBuV |
| Resolution | 1dB |
| Accuracy | ±1dB |
| Sensor sensitivity | -65dB (0dB=1V/ubar RMS SPL) |
| Sensor center frequency | 40kHz |
| Frequency range | 20~100kHz |
| Sensor diameter | 16mm |
| Heterodyne frequency | 38.4kHz |
3. HFCT measurement
| Item | Specification |
| Sensor type | HFCT |
| Range | 0pC~25000pC |
| Minimum impulse rate | 10Hz |
| Frequency response | 100kHz~20MHz |
| Inner diameter | 45mm(customization available) |
| Outer diamete | 107 mm(customization available) |
| Output impedance | 50Ω |
| Output interface | BNC connector |
4. Temperature measurement
| Item | Specification |
| Sensor type | Infrared sensor |
| Range | -20℃~150℃ |
| Accuracy | ±1% or 1℃ |
| Response wave length | 8~14um |
| Distance coefficient | 15:1 |
| Sending rate | 0.95 |
| IP degree | 65 |
| Humidity | 0~90% RD |
| Size: | Φ20X90 |
5. Size & Weight: 240mm×125mm×60mm / 1.2kg
6. Rated input supply for charger: 90-264V AC/ 47-63HZ, charging voltage 12V DC